Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.657
Filtrar
1.
Anal Chem ; 96(15): 5852-5859, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38556977

RESUMO

A multicolor electrochemiluminescence (ECL) biosensor based on a closed bipolar electrode (BPE) array was proposed for the rapid and intuitive analysis of three prostate cancer staging indicators. First, [Irpic-OMe], [Ir(ppy)2(acac)], and [Ru(bpy)3]2+ were applied as blue, green, and red ECL emitters, respectively, whose mixed ECL emission colors covered the whole visible region by varying the applied voltages. Afterward, we designed a simple Mg2+-dependent DNAzyme (MNAzyme)-driven tripedal DNA walker (TD walker) to release three output DNAs. Immediately after, three output DNAs were added to the cathodic reservoirs of the BPE for incubation. After that, we found that the emission colors from the anode of the BPE changed as a driving voltage of 8.0 V was applied, mainly due to changes in the interfacial potential and faradaic currents at the two poles of the BPE. Via optimization of the experimental parameters, cutoff values of such three indicators at different clinical stages could be identified instantly with the naked eye, and standard precision swatches with multiple indicators could be prepared. Finally, in order to precisely determine the prostate cancer stage, the multicolor ECL device was used for clinical analysis, and the resulting images were then compared with standard swatches, laying the way for accurate prostate cancer therapy.


Assuntos
Técnicas Biossensoriais , Neoplasias da Próstata , Masculino , Humanos , Medições Luminescentes/métodos , Fotometria , Neoplasias da Próstata/diagnóstico , Antígeno Prostático Específico , DNA , Técnicas Biossensoriais/métodos , Eletrodos , Técnicas Eletroquímicas/métodos
2.
Anal Chem ; 96(15): 6037-6044, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38560885

RESUMO

Dopamine (DA), an essential neurotransmitter, is closely associated with various neurological disorders, whose real-time dynamic monitoring is significant for evaluating the physiological activities of neurons. Electrochemical sensing methods are commonly used to determine DA, but they mostly rely on the redox reaction of its o-phenolic hydroxyl group, which makes it difficult to distinguish it from substances with this group. Here, we design a biomimetic nanozyme inspired by the coordination structure of the copper-based active site of dopamine ß-hydroxylase, which was successfully synthesized via a urea-mediated MOF pyrolysis reconstruction strategy. Experimental studies and theoretical calculations revealed that the nanozyme with Cu-N3 coordination could hydroxylate the carbon atom of the DA ß-site at a suitable potential and that the active sites of this Cu-N3 structure have the lowest binding energy for the DA ß-site. With this property, the new oxidation peak achieves the specific detection of DA rather than the traditional electrochemical signal of o-phenol hydroxyl redox, which would effectively differentiate it from neurotransmitters, such as norepinephrine and epinephrine. The sensor exhibited good monitoring capability in DA concentrations from 0.05 to 16.7 µM, and its limit of detection was 0.03 µM. Finally, the sensor enables the monitoring of DA released from living cells and can be used to quantitatively analyze the effect of polystyrene microplastics on the amount of DA released. The research provides a method for highly specific monitoring of DA and technical support for initial screening for neurocytotoxicity of pollutants.


Assuntos
Dopamina , Oxigenases de Função Mista , Dopamina/química , Fenol , Biomimética , Cobre , Plásticos , Pirólise , Eletrodos , Neurotransmissores , Técnicas Eletroquímicas/métodos
3.
Anal Chem ; 96(15): 6079-6088, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38563576

RESUMO

Metal ion homeostasis is imperative for normal functioning of the brain. Considering the close association between brain metal ions and various pathological processes in brain diseases, it becomes essential to track their dynamics in awake animals for accurate physiological insights. Although ion-selective microelectrodes (ISMEs) have demonstrated great advantage in recording ion signals in awake animals, their intrinsic potential drift impairs their accuracy in long-term in vivo analysis. This study addresses the challenge by integrating ISMEs with photoelectrochemical (PEC) sensing, presenting an excitation-detection separated PEC platform based on potential regulation of ISMEs. A flexible indium tin oxide (Flex-ITO) electrode, modified with MoS2 nanosheets and Au NPs, serves as the photoelectrode and is integrated with a micro-LED. The integrated photoelectrode is placed on the rat skull to remain unaffected by animal activity. The potential of ISME dependent on the concentration of target K+ serves as the modulator of the photocurrent signal of the photoelectrode. The proposed design allows deep brain detection while minimizing interference with neurons, thus enabling real-time monitoring of neurochemical signals in awake animals. It successfully monitors changes in extracellular K+ levels in the rat brain after exposure to PM2.5, presenting a valuable analytical tool for understanding the impact of environmental factors on the nervous system.


Assuntos
Técnicas Biossensoriais , Vigília , Animais , Ratos , Encéfalo , Microeletrodos , Técnicas Eletroquímicas
4.
Langmuir ; 40(15): 7974-7981, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38564230

RESUMO

An electrochemical impedimetric biosensing platform with lectin as a molecular recognition element has been established for the sensitive detection of glycoproteins, a class of important biomarkers in clinical diagnosis. One of the representative metal-organic framework materials, MIL-101(Cr)-NH2, was utilized as the supporting matrix, and its amino groups served as the anchors to immobilize the lectins of concanavalin A (Con A), constituting Con A@MIL-101(Cr)-NH2 for the determination of invertase (INV) as a model glycoprotein. The Con A concentration, immobilization time, and incubation time with INV were optimized. Under the optimal conditions, the degree of impedance increase was linearly proportional to the logarithm of INV concentration between 1.0 × 10-16 and 1.0 × 10-11 M, affording a limit of detection as low as 3.98 × 10-18 M. Good specificity, stability, reproducibility, and repeatability were demonstrated for the fabricated biosensing platform. Moreover, real mouse serum samples were spiked with different concentrations of INV. Excellent recoveries were obtained, which demonstrated the biosensing platform's capability of analyzing glycoproteins within a complex matrix.


Assuntos
Técnicas Biossensoriais , Estruturas Metalorgânicas , Animais , Camundongos , Concanavalina A , Estruturas Metalorgânicas/química , Reprodutibilidade dos Testes , Lectinas/química , Glicoproteínas , Técnicas Eletroquímicas , Limite de Detecção
5.
J Colloid Interface Sci ; 665: 934-943, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38569310

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are excellent alternative luminophores for electrochemiluminescence (ECL) immunoassays. However, they are inevitably limited by the aggregation-caused quenching effect. In this study, aimed at eliminating the aggregation quenching of PAHs, luminescent metal-organic frameworks (MOFs) with 1,3,6,8-tetra(4-carboxybenzene)pyrene (H4TBAPy) as the ligand were exploited as a novel nano-emitter for the construction of ECL immunoassays. The luminophore exhibits efficient aggregation-induced emission enhancement, good acid-base resistance property and unusual ECL reactivity. In addition, the simultaneous use of potassium persulfate and hydrogen peroxide as dual co-reactants resulted in a synergistic enhancement of the cathodic ECL efficiency. The use of magnetic iron-nickel alloys as the multifunctional sensing platform can further enhance the ECL activity, and its enriched zero-valent iron as a co-reactant accelerator effectively drives ECL analytical performance. Profiting from the excellent characteristics, signal-on ECL immunoassays have been constructed. With carcinoembryonic antigen as the model analysis target, a detection limit of 0.63 pg/mL was obtained within the linear range of 1 pg/mL to 50 ng/mL, accompanied by excellent analytical performance. This report opens a new window for the rational design of efficient ECL illuminators, and the proposed ECL immunoassays may find promising applications in the detection of disease markers.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Estruturas Metalorgânicas , Hidrocarbonetos Policíclicos Aromáticos , Pirenos , Imunoensaio , Ferro , Medições Luminescentes , Técnicas Eletroquímicas , Limite de Detecção
6.
Chemosphere ; 355: 141855, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38570051

RESUMO

Wastewater polluted by organics can be treated by using electro-generated active chlorine, even if this promising route presents some important drawbacks such as the production of chlorinated by-products. Here, for the first time, this process was studied in a microfluidic electrochemical reactor with a very small inter-electrode distance (145 µm) using a water solution of NaCl and phenol and a BDD anode. The potential production of chloroacetic acids, chlorophenols, carboxylic acids, chlorate and perchlorate was carefully evaluated. It was shown, for the first time, up to our knowledge, that the use of the microfluidic device allows to perform the treatment under a continuous mode and to achieve higher current efficiencies and a lower generation of some important by-products such as chlorate and perchlorate. As an example, the use of the microfluidic apparatus equipped with an Ag cathode allowed to achieve a high removal of total organic carbon (about 76%) coupled with a current efficiency of 17% and the production of a small amount of chlorate (about 30 ppm) and no perchlorate. The effect of many parameters (namely, flow rate, current density and nature of cathode) was also investigated.


Assuntos
Cloro , Poluentes Químicos da Água , Técnicas Eletroquímicas , Percloratos , Microfluídica , Água , Cloratos , Cloretos , Oxirredução , Eletrodos , Poluentes Químicos da Água/análise
7.
Biomed Microdevices ; 26(2): 21, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558326

RESUMO

Kirigami is one of the interesting paper art forms and the modified sub-class of origami. Kirigami paper art is widely employed in a variety of applications, and it is currently being used in biosensors because of its outstanding advantages. This is the first study on the use of a Kirigami-based aptasensor for DENV (Dengue virus)-antigen detection. In this study, the kirigami approach has been utilized to develop a stretchable, movable, and flexible sensor. The constructed stretchable-kirigami electrode helps in adjusting the connection of electrodes without disturbing the electrochemical cell zone during the experiment. To increase the sensitivity of this biosensor we have synthesized Ag-NPs (Silver nanoparticles) via chemical methods and characterized their results with the help of TEM & UV-Vis Spectroscopy. Different electrochemical approaches were used to validate the sensor response i.e., CV (Cyclic voltammetry) and LSV (Linear sweep voltammetry), which exhibited great detection capability towards dengue virus with the range of 0.1 µg/ml to 1000 µg/ml along with a detection limit of 0.1 µg/ml and showing no reactivity to the chikungunya virus antigen, making it more specific to the DENV antigen. Serum (healthy-human) was also successfully applied to validate the results of the constructed aptasensor. Integration of the Kirigami approach form with the electrochemical aptasensor that utilizes a 3-E setup (three-electrode setup) which is referred to as a tripod and collectively called Kirigami-tripod-based aptasensor. Thus, the developed integrated platform improves the sensors capabilities in terms of cost efficiency, high stretchability, and sensitivity.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Dengue , Nanopartículas Metálicas , Humanos , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Aptâmeros de Nucleotídeos/química , Ouro/química , Prata/química , Técnicas Biossensoriais/métodos , Eletrodos , Dengue/diagnóstico , Limite de Detecção
8.
ACS Appl Mater Interfaces ; 16(14): 17300-17312, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38557010

RESUMO

Early secretory antigenic target-6 (ESAT-6) is regarded as the most immunogenic protein produced by Mycobacterium tuberculosis, whose detection is of great clinical significance for tuberculosis diagnosis. However, the detection of the ESAT-6 antigen has been hampered by the expensive cost and complex experimental procedures, resulting in low sensitivity. Herein, we developed a titanium carbide (Ti3C2Tx)-based aptasensor for ESAT-6 detection utilizing a triple-signal amplification strategy. First, acetylene black (AB) was immobilized on Ti3C2Tx through a cross-linking reaction to form the Ti3C2Tx-AB-PAn nanocomposite. Meanwhile, AB served as a conductive bridge, and Ti3C2Tx can synergistically promote the electron transfer of PAn. Ti3C2Tx-AB-PAn exhibited outstanding conductivity, high electrochemical signals, and abundant sites for the loading of ESAT-6 binding aptamer II (EBA II) to form a novel signal tag. Second, N-CNTs were adsorbed on NiMn layered double hydride (NiMn LDH) nanoflowers to obtain NiMn LDH/N-CNTs, exhibiting excellent conductivity and preeminent stability to be used as electrode modification materials. Third, the biotinylated EBA (EBA I) was immobilized onto a streptavidin-coated sensing interface, forming an amplification platform for further signal enhancement. More importantly, as a result of the synergistic effect of the triple-signal amplification platform, the aptasensor exhibited a wide detection linear range from 10 fg mL-1 to 100 ng mL-1 and a detection limit of 4.07 fg mL-1 for ESAT-6. We envision that our aptasensor provides a way for the detection of ESAT-6 to assist in the diagnosis of tuberculosis.


Assuntos
Compostos de Anilina , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Mycobacterium tuberculosis , Tuberculose , Humanos , Acetileno , Adsorção , Limite de Detecção , Titânio , Tuberculose/diagnóstico , Estreptavidina , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos
9.
Biosens Bioelectron ; 255: 116263, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38593715

RESUMO

Aggregation-induced electrochemiluminescence (AIECL) technology has aroused widespread interest due to the significant improve in ECL response by solving the problems of aggregation-caused quenching and poor water solubility of the luminophore. However, the existing AIECL emitters still suffer from low ECL efficiency, additional coreactants and complex synthesis steps, which greatly limit their applications. Herein, luminol, as a kind of AIE molecule, was assembled with Zn2+ nodes to obtain a novel microflower-like Zinc-luminol metal-organic gel (Zn-MOG) by one-step method. In the light of the strong affinity of N atoms in luminol ligand to Zn2+, Zn-MOG with vigorous viscosity and stability can be formed immediately after vortex oscillation, overcoming the main difficulties of the complicated synthesis steps and poor film-forming performance encountered in current AIECL materials. Impressively, an AIECL resonance energy transfer (RET) biosensor was constructed using Zn-MOG as a donor and Alexa Fluor 430 as an acceptor in combination with DNA-Fuel-driven target recycling amplification for the ultrasensitive detection of PiRNA-823. The fabricated biosensor exhibited a wide linear relationship in the range of 100 aM to 100 pM and a detection limit as low as 60.0 aM. This work is the first to realize the construction of ECL emitters using the AIE effect of luminol, which provides inspiration for the design of AIECL systems without adding coreactants.


Assuntos
Técnicas Biossensoriais , Luminol , Zinco , RNA de Interação com Piwi , Medições Luminescentes/métodos , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Limite de Detecção , Metais
10.
Anal Chim Acta ; 1304: 342558, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637055

RESUMO

Quorum sensing signal molecule is an important biomarker released by some microorganisms, which can regulate the adhesion and aggregation of marine microorganisms on the surface of engineering facilities. Thus, it is significant to exploit a convenient method that can effectively monitor the formation and development of marine biofouling. In this work, an advanced photoelectrochemical (PEC) aptamer biosensing platform was established and firstly applied for the rapid and ultrasensitive determination of N-(3-Oxodecanoyl)-l-homoserine lactone (3-O-C10-HL) released from marine fouling microorganism Ponticoccus sp. PD-2. The visible-light-driven Bi2WO6/Bi2S3 heterojunction derived from metal-organic frameworks (MOFs) CAU-17 and self-screened aptamer were employed as the photoactive materials and bioidentification elements, respectively. Appropriate amount of MoS2 quantum dots (QDs) conjugated with single-stranded DNA were introduced by hybridization to enhance the photocurrent response of the PEC biosensor. The self-screening aptamer can specifically recognize 3-O-C10-HL, accompanied by increasing the steric hindrance and forcing MoS2 QDs to leave the electrode surface, resulting in an obvious reduction of photocurrent and achieving a dual-inhibition signal amplification effect. Under the optimized conditions, the photocurrent response of PEC aptasensor was linear with 3-O-C10-HL concentration from 1 nM to 10 µM, and the detection limit was as low as 0.26 nM. The detection strategy also showed a high reproducibility, superior specificity and good stability. This work not only provides a simple, rapid and ultrasensitive PEC aptamer biosensing strategy for monitoring quorum sensing signal molecules in marine biofouling, but also broadens the application of MOFs-based heterojunctions in PEC sensors.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas/métodos , Reprodutibilidade dos Testes , Molibdênio , Percepção de Quorum , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Limite de Detecção
11.
Artigo em Inglês | MEDLINE | ID: mdl-38613456

RESUMO

In the current work, a rapid, selective, and sensitive technique was developed for the detection of Alizarin Red S (ARS) by applying poly leucine modified carbon paste electrode (PLMCPE). Electrochemical impedance spectroscopy (EIS) and Scanning electron microscopy (SEM) were utilized to study the surface morphology of unmodified carbon paste electrode (UMCPE) and PLMCPE. The active surface area for UMCPE and PLMCPE was found to be 0.0012 cm2 and 0.0026 cm2 respectively. The electrochemical response of ARS at UMCPE and PLMCPE was analyzed using cyclic voltammetry (CV) in the potential window of 0.4 to 1.0 V. The cyclic voltammogram obtained for varying the pH of 0.2 M phosphate buffer (PB) solution showed maximum current for the oxidation of ARS at pH 6.5. The electrochemical reaction of ARS was found to be irreversible and adsorption controlled. The effect of variation of concentration of ARS on the oxidation peak current was evaluated using CV and linear scan voltammetry (LSV). A linear relationship between the concentration variation and current was obtained in the linear range of 1.5 µM-3.5 µM and 0.2 µM-5.0 µM for CV and LSV respectively. The limit of detection (LOD) of 0.68 µM for the CV method and 0.29 µM for the LSV method was exhibited by the developed sensor. The simultaneous study of ARS along with tartrazine (TZ) showed good selectivity for ARS. The interferents of foreign molecules showed no effect on the selectivity of the electrode. The applicability of PLMCPE on real samples gave good recovery ranging from 97.46-101.2%; hence, the sensor can be utilized on real samples. The developed sensor has good stability and sensitivity.


Assuntos
Antraquinonas , Carbono , Tartrazina , Carbono/química , Leucina , Eletrodos , Técnicas Eletroquímicas/métodos
12.
Anal Chem ; 96(14): 5446-5454, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38556805

RESUMO

In this study, a novel integrated photoelectrochemical (PEC) sensor platform was proposed, utilizing an optical fiber (OF) as the working electrode for guided in situ light. A CdS quantum dots (QDs)/ZnO nanosheets (NSs) n-n heterojunction was quickly and easily constructed on the OF surface by successive ionic layer adsorption and reaction (SILAR). Au nanoparticles (NPs)@dsDNA as a capturing probe were modified on the CdS QDs/ZnO NSs@OF (CZ@OF). Due to the energy transfer between Au NPs@dsDNA and CdS QDs, the resultant opto-electrode has a lower background near zero, enabling the "signal-on" detection of biomarkers (interleukin-6 (IL-6) as a model). The OF-PEC biosensor demonstrated a wide linear range from 1 to 100 pg mL-1 with a regression coefficient (R2) of 0.9958 and an impressive detection limit (LOD) of 0.19 pg mL-1. More significantly, the proposed OF-PEC can be successfully used for the detection of IL-6 in serum samples from patients with pulmonary arterial hypertension, and it showed consistency and is more sensitive to trace concentrations compared to BD FACSCanto II flow cytometry used at the hospital. This holds significance for an early disease diagnosis. Therefore, the proposed OF-PEC not only achieves integration of the light source and sensing interface but also enables sensitive and accurate "signal-on" detection of IL-6. Furthermore, due to the flexibility and remote detection capabilities of OF, the application of OF-PEC is expected to be expanded more widely. This approach opens up possibilities for advances in PEC sensing.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Pontos Quânticos , Óxido de Zinco , Humanos , Técnicas Eletroquímicas , Citocinas , Interleucina-6 , Ouro , Adsorção , Fibras Ópticas , Eletrodos , Limite de Detecção
13.
ACS Appl Bio Mater ; 7(4): 2488-2498, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38577953

RESUMO

Green synthesis approaches for making nanosized ceria using starch from cassava as template molecules to control the particle size are reported. The results of the green synthesis of ceria with an optimum calcination temperature of 800 °C shows a size distribution of each particle of less than 30 nm with an average size of 9.68 nm, while the ratio of Ce3+ to Ce4+ was 25.6%. The green-synthesized nanoceria are applied to increase the sensitivity and attach biomolecules to the electrode surface of the electrochemical aptasensor system for coronavirus disease (COVID-19). The response of the aptasensor to the receptor binding domain of the virus was determined with the potassium ferricyanide redox system. The screen-printed carbon electrode that has been modified with green-synthesized nanoceria shows 1.43 times higher conductivity than the bare electrode, while those modified with commercial ceria increase only 1.18 times. Using an optimized parameter for preparing the aptasensors, the detection and quantification limits were 1.94 and 5.87 ng·mL-1, and the accuracy and precision values were 98.5 and 89.1%. These results show that green-synthesized ceria could be a promising approach for fabricating an electrochemical aptasensor.


Assuntos
Técnicas Biossensoriais , COVID-19 , Cério , Manihot , Nanopartículas , Carbono/química , SARS-CoV-2 , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , Nanopartículas/química , Eletrodos
14.
Anal Chim Acta ; 1304: 342562, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637031

RESUMO

A sensitive electrochemical platform was constructed with NH2-Cu-MOF as electrochemical probe to detect antibiotics using CRISPR/Cas12a system triggered by hybridization chain reaction (HCR). The sensing system consists of two HCR systems. HCR1 occurred on the electrode surface independent of the target, generating long dsDNA to connect signal probes and producing a strong electrochemical signal. HCR2 was triggered by target, and the resulting dsDNA products activated the CRISPR/Cas12a, thereby resulting in effective and rapid cleavage of the trigger of HCR1, hindering the occurrence of HCR1, and reducing the number of NH2-Cu-MOF on the electrode surface. Eventually, significant signal change depended on the target was obtained. On this basis and with the help of the programmability of DNA, kanamycin and ampicillin were sensitively detected with detection limits of 60 fM and 10 fM (S/N = 3), respectively. Furthermore, the sensing platform showed good detection performance in milk and livestock wastewater samples, demonstrating its great application prospects in the detection of antibiotics in food and environmental water samples.


Assuntos
Antibacterianos , Técnicas Biossensoriais , Técnicas Eletroquímicas/métodos , Sistemas CRISPR-Cas , Técnicas Biossensoriais/métodos , Hibridização de Ácido Nucleico
15.
Anal Chim Acta ; 1304: 342524, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637033

RESUMO

The inappropriate use of antibiotics undoubtedly poses a potential threat to public health, creating an increasing need to develop highly sensitive tests. In this study, we designed a new type of porphyrin metal-organic frameworks (Fe TCPP(Zn) MOFs) with homogeneous catalytic sites. The ferric-based metal ligands of Fe TCPP(Zn) MOFs acted as co-reaction accelerators, which effectively improved the conversion efficiency of H2O2 on the surface of MOFs, then increased the concentration of •OH surrounding porphyrin molecules to achieve self-enhanced electrochemiluminescence (ECL). Based on this, an aptasensor for the specific detection of kanamycin (KAN) in food and environmental water samples was constructed in combination with resonance energy transform (RET), in which Fe TCPP(Zn) MOFs were used as luminescence donor and AuNPs were used as acceptor. Under the best conditions, there was a good linear relationship between the ECL intensity and the logarithm of KAN concentration with a detection limit of 0.28 fM in the range of 1.0 × 10-7-1.0 × 10-13 M, demonstrating satisfactory selectivity and stability. At the same time, the complexity of the detection environment was reduced, which further realized the reliable analysis of KAN in milk, honey and pond water. Overall, this innovative self-enhanced ECL strategy provides a novel approach for constructing efficient ECL systems in MOFs, and also extends the application of MOFs to the analysis and detection of trace antibiotics in food and the environment.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Metaloporfirinas , Canamicina/análise , Ouro , Domínio Catalítico , Peróxido de Hidrogênio , Medições Luminescentes , Antibacterianos/análise , Técnicas Eletroquímicas , Água , Limite de Detecção
16.
Anal Chim Acta ; 1304: 342561, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637057

RESUMO

Size selectivity is crucial in highly accurate preparation of biosensors. Herein, we described an innovative electrochemiluminescence (ECL) sensing platform based on the confined DNA tetrahedral molecular sieve (DTMS) for size-selective recognition of nucleic acids and small biological molecule. Firstly, DNA template (T) was encapsulated into the inner cavity of DNA tetrahedral scaffold (DTS) and hybridized with quencher (Fc) labeled probe DNA to prepare DTMS, accordingly inducing Ru(bpy)32+ and Fc closely proximate, resulting the sensor in a "signal-off" state. Afterwards, target molecules entered the cavity of DTMS to realize the size-selective molecular recognition while prohibiting large molecules outside of the DTMS, resulting the sensor in a "signal-on" state due to the release of Fc. The rigid framework structure of DTS and the anchor of DNA probe inside the DTS effectively avoided the nuclease degradation of DNA probe, and nonspecific protein adsorption, making the sensor possess potential application prospect for size-selective molecular recognition in diagnostic analysis with high accuracy and specificity.


Assuntos
Técnicas Biossensoriais , Medições Luminescentes , Medições Luminescentes/métodos , Fotometria , Técnicas Biossensoriais/métodos , DNA , Sondas de DNA , Técnicas Eletroquímicas/métodos
17.
Mikrochim Acta ; 191(5): 240, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573400

RESUMO

Improving novel and efficient biosensors for determining organic/inorganic compounds is a challenge in analytical chemistry for clinical diagnosis and research in biomedical sciences. Electrochemical enzyme-based biosensors are one of the commercially successful groups of biosensors that make them highly appealing because of their low cost, high selectivity, and sensitivity. Core/shell nanoparticles have emerged as versatile platforms for developing enzyme-based electrochemical biosensors due to their unique physicochemical properties and tunable surface characteristics. This study provides a comprehensive review of recent trends and advancements in the utilization of core/shell nanoparticles for the development of enzyme-based electrochemical biosensors. Moreover, a statistical evaluation of the studies carried out in this field between 2007 and 2023 is made according to the preferred electrochemical techniques. The recent applications of core/shell nanoparticles in enzyme-based electrochemical biosensors were summarized to quantify environmental pollutants, food contaminants, and clinical biomarkers. Additionally, the review highlights recent innovations and strategies to improve the performance of enzyme-based electrochemical biosensors using core/shell nanoparticles. These include the integration of nanomaterials with specific functions such as hydrophilic character, chemical and thermal stability, conductivity, biocompatibility, and catalytic activity, as well as the development of new hybrid nanostructures and multifunctional nanocomposites.


Assuntos
Poluentes Ambientais , Nanocompostos , Nanopartículas , Condutividade Elétrica , Técnicas Eletroquímicas
18.
Sci Rep ; 14(1): 8099, 2024 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582770

RESUMO

The simultaneous identification of drugs has considerable difficulties due to the intricate interplay of analytes and the interference present in biological matrices. In this study, we introduce an innovative electrochemical sensor that overcomes these hurdles, enabling the precise and simultaneous determination of morphine (MOR), methadone (MET), and uric acid (UA) in urine samples. The sensor harnesses the strategically adapted carbon nanotubes (CNT) modified with graphitic carbon nitride (g-C3N4) nanosheets to ensure exceptional precision and sensitivity for the targeted analytes. Through systematic optimization of pivotal parameters, we attained accurate and quantitative measurements of the analytes within intricate matrices employing the fast Fourier transform (FFT) voltammetry technique. The sensor's performance was validated using 17 training and 12 test solutions, employing the widely acclaimed machine learning method, partial least squares (PLS), for predictive modeling. The root mean square error of cross-validation (RMSECV) values for morphine, methadone, and uric acid were significantly low, measuring 0.1827 µM, 0.1951 µM, and 0.1584 µM, respectively, with corresponding root mean square error of prediction (RMSEP) values of 0.1925 µM, 0.2035 µM, and 0.1659 µM. These results showcased the robust resiliency and reliability of our predictive model. Our sensor's efficacy in real urine samples was demonstrated by the narrow range of relative standard deviation (RSD) values, ranging from 3.71 to 5.26%, and recovery percentages from 96 to 106%. This performance underscores the potential of the sensor for practical and clinical applications, offering precise measurements even in complex and variable biological matrices. The successful integration of g-C3N4-CNT nanocomposites and the robust PLS method has driven the evolution of sophisticated electrochemical sensors, initiating a transformative era in drug analysis.


Assuntos
Nanocompostos , Nanotubos de Carbono , Morfina , Ácido Úrico/urina , Reprodutibilidade dos Testes , Técnicas Eletroquímicas/métodos
19.
Anal Chim Acta ; 1302: 342492, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38580406

RESUMO

The rational design of DNA tracks is an effective pathway to guide the autonomous movement and high-efficiency recognition in DNA walkers, showing outstanding advantages for the cascade signal amplification of electrochemical biosensors. However, the uncontrolled distance between two adjacent tracks on the electrode could increase the risk of derailment and interruption of the reaction. Hence, a novel four-way balanced cruciform-shaped DNA track (C-DNT) was designed as a structured pathway to improve the effectiveness and stability of the reaction in DNA walkers. In this work, two kinds of cruciform-shaped DNA were interconnected as a robust structure that could avoid the invalid movement of the designed DNA walker on the electrode. When hairpin H2 was introduced onto the electrode, the strand displacement reaction (SDR) effectively triggered movements of the DNA walker along the cruciform-shaped track while leaving ferrocene (Fc) on the electrode, leading to a significant enhancement of the electrochemical signal. This design enabled the walker to move in an excellent organized and controllable manner, thus enhancing the reaction speed and walking efficiency. Compared to other walkers moving on random tracks, the reaction time of the C-DNT-based DNA walker could be reduced to 20 min. Lead ion (Pb2+) was used as a model target to evaluate the analytical performance of this biosensor, which exhibited a low detection limit of 0.033 pM along with a wide detection ranging from 0.1 pM to 500 nM. This strategy presented a novel concept for designing a high-performance DNA walker-based sensing platform for the detection of contaminants.


Assuntos
Técnicas Biossensoriais , Chumbo , DNA Cruciforme , Limite de Detecção , DNA/química , Técnicas Eletroquímicas
20.
Anal Chim Acta ; 1302: 342494, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38580414

RESUMO

BACKGROUND: Thrombin, a coagulation system protease, is a key enzyme involved in the coagulation cascade and has been developed as a marker for coagulation disorders. However, the methods developed in recent years have the disadvantages of complex operation, long reaction time, low specificity and sensitivity. Meanwhile, thrombin is at a lower level in the pre-disease period. Therefore, to accurately diagnose the disease, it is necessary to develop a fast, simple, highly sensitive and specific method using signal amplification technology. RESULTS: We designed an electrochemical biosensor based on photocatalytic atom transfer radical polymerization (photo-ATRP) signal amplification for the detection of thrombin. Sulfhydryl substrate peptides (without carboxyl groups) are self-assembled to the gold electrode surface via Au-S bond and serve as thrombin recognition probes. The substrate peptide is cleaved in the presence of thrombin to generate -COOH, which can form a carboxylate-Zr(IV)-carboxylate complex via Zr(IV) and initiator (α-bromophenylacetic acid, BPAA). Subsequently, an electrochemical biosensor was prepared by introducing polymer chains with electrochemical signaling molecules (ferrocene, Fc) onto the electrode surface by photocatalytic (perylene, Py) mediated ATRP using ferrocenylmethyl methacrylate (FMMA) as a monomer. The concentration of thrombin was evaluated by the voltammetric signal generated by square wave voltammetry (SWV), and the result showed that the biosensor was linear between 1.0 ng/mL âˆ¼ 10 fg/mL, with a lower detection limit of 4.0 fg/mL (∼0.1 fM). Moreover, it was shown to be highly selective for thrombin activity in complex serum samples and for thrombin inhibition screening. SIGNIFICANCE: The biosensor is an environmentally friendly and economically efficient strategy while maintaining the advantages of high sensitivity, anti-interference, good stability and simplicity of operation, which has great potential for application in the analysis of complex samples.


Assuntos
Técnicas Biossensoriais , Perileno , DNA/química , Trombina , Polimerização , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Peptídeos , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...